Problem ymptom | Possible Cause可能的原因 | Recommended Action |
ON / OFF Switch is on but the A/C Indicator does not light ON / OFF开关上,但阿/指示灯不亮 | 1. Primary power disconnect is in OFF position. 2. Primary fuses / breakers are blown or tripped. 3. Units internal fuse blown. 4. Faulty components in unit. 1。主电源断开在OFF位置。2。保险丝/断路器被炸毁或跳闸。 3。内部单元保险丝熔断。 4。内部单元有瑕疵。 | 1. Turn primary power disconnect switch to ON position. 2. a) Have qualified person check primary fuses / breakers. b) Connect unit to known good primary power receptacle 3. a) Replace fuse. b) If fuse blows again, return to authorized service center for repair or replacement. 4. Return to authorized service center for repair or replacement. 1。打开主电源断开开关ON位置。 2。 1)有资格的人主要检查保险丝/断路器。二)连接单位已知良好的初级电源插座3。 1)更换保险丝。 b)如果保险丝打击再次返回修理或更换授权的服务中心。 4。返回修理或更换授权的服务中心。 |
Fault indicator flashing, 65 PSI indicator flashing 故障指示灯闪烁,指示灯闪烁65防扩散安全倡议 | 1. INPUT VOLTAGE SELECTION SWITCH set for incorrect voltage. 2. Primary input voltage problem. 3. Faulty components in unit. 1。输入电压选择开关设置不正确电压。 2。初级输入电压的问题。 3。部分单元故障 | 1. Set INPUT VOLTAGE SELECTION SWITCH to match primary input voltage. 2. Have qualified person check primary voltage to insure it meets unit requirements see section 2.05. 3. Return to authorized service center for repair or replacement. 1。设置输入电压选择开关,以配合主要输入电压。2。有资格的人检查初级电压以确保其符合要求的单位,见第2.05。 3。返回修理或更换授权的服务中心。 |
TEMPERATURE indicator on. FAULT indicator flashing. 温度指标。故障指示灯闪烁。 | 1. Air flow through or around the unit is obstructed. 2. Duty cycle of the unit has been exceeded 3. Failed components in unit 1。通过空气或周围单位流动受阻。 2。责任单位的周期已经超过 3。出现故障的组件单位 | 1. Refer to clearance information – section 2.04 2. Allow unit to cool. 3. Return to authorized service center for repair or replacement. 1。关信息,请参阅-第2.04 2。允许单位冷却。 3。返回修理或更换授权的服务中心。 |
GAS LED off, FAULT and MIN pressure indicators flashing. 气体的LED关闭,故障和闵压力指标闪烁。 | 1. Gas supply not connected to unit. 2. Gas supply not turned on. 3. Gas supply pressure too low. 4. AIR PRESSURE CONTROL regulator set too low. 5. Failed components in unit. 1。天然气供应没有连接到单位。 2。供气未打开。3。供气压力过低。 4。气压控制调节定得太低。 5。单位失败的组件。 | 1. Connect gas supply to unit. 2. Turn gas supply on. 3. Set air supply inlet pressure to unit to 120 psi. 4. Adjust regulator to set air pressure - see section 4.02. 5. Return to authorized service center for repair or replacement. 1。连接燃气供应单位。 2。打开煤气供应问题。 3。设置空气供应进口压力的单位120防扩散安全倡议。 4。调整监管机构设置气压-见第4.02。 5。返回修理或更换授权的服务中心。 |
FAULT and 70 PSI indicators flashing. 闪光的故障和 70 PSI 指标。 | 1. Shield Cup loose. 2. Torch not properly connected to power supply. 3. Problem in torch and leads PIP circuit. 4. Failed components in unit. . 盾杯松散。 2.火炬不正确连接到电源。 3.火炬和线索 PIP 电路中的问题。 4.失败单元中的组件 | 1. Hand tighten the shield cup until it is snug. 2. Insure torch ATC is securely fastened to unit. 3. Replace torch and leads or return to authorized service center for repair or replacement. 4. Return to authorized service center for repair or replacement. 1.手拧紧盾杯,直到它很舒适。 2.确保航空交通管制情形下到单位的火炬。3.取代火炬和线索或返回到授权的服务中心进行维修或更换。 4.回到授权的服务中心进行维修或更换。 |
FAULT and 75 PSI indicators flashing. 闪光的故障和 75 PSI 指标 | 1. Start signal is active when ON/OFF SWITCH is turned to ON position. 2. Problem in the torch and leads switch circuit. 3. Failed components in unit. 1 SWITCH ON/OFF 处于打开状态时对位置,活动.开始信号。 2.火炬和潜在顾客开关电路中的问题。 3.失败单元中的组件 | 1. Start can be active for one of the following: ? Hand torch switch held closed ? Hand pendant switch held closed ? CNC START signal is active low Release the START signal source 2. Replace torch and leads or return to authorized service center for repair or replacement. 3. Return to authorized service center for repair or replacement. 1.启动处于活动状态为下列之一: ? 手火炬开关举行闭的 ? 手垂饰开关举行闭的 ? 数控 START 的信号是活动低释放 START 信号源 2。替换火炬和线索或返回到授权的服务中心进行维修或更换。 3.回到进行维修或更换获授权的服务中心 |
FAULT & 80 PSI indicators flashing. Gas flow is cycling on and off. 闪光的指标断裂 & 80 PSI。气体流量循环和关闭。 | 1. Torch shield cup is loose. 2. Torch tip, electrode or starter cartridge missing.3. Torch start cartridge is stuck. 4. Open conductor in torch leads.5. Problem in the torch and leads switch circuit.6. Failed components in unit. 1.火炬盾杯松了。2.火炬提示、 电极或起动器墨盒 missing.3。火炬开始墨盒是卡。4.打开火炬 leads.5 中的导体。火炬和潜在顾客开关 circuit.6 中存在的问题。单元中的失败的组件。 | 1. Tighten shield cup by hand. Do not overtighten. 2. Turn off power supply. Remove shield cup. Install missing parts.3. Turn off power supply. Bleed down system pressure. Remove shield cup, tip and start cartridge. Check start cartridge lower end fitting for free movement. Replace if fitting does not move freely.4. Replace torch and leads or return to authorized service center for repair or replacement.5. Replace torch and leads or return to authorized service center for repair or replacement.6.Return to authorized service center for repair or replacement. 1.用手收紧盾杯。不 overtighten。2.关闭电源供应。删除盾杯。安装缺少的 parts.3。关闭电源供应。系统压力下流血。删除盾杯、 提示和启动磁带。检查免费装运动的开始墨盒下结束。如果安装不会移动 freely.4,替换。替换火炬和线索或返回到授权的服务中心进行维修或 replacement.5。替换火炬和线索或返回到授权的服务中心进行维修或授权的服务中心进行维修或更换为 replacement.6.Return。 |
Nothing happens when torch switch or remote switch is closed ( Or CNC START signal is active) No gas flow, DC LED OFF. 没有任何反应时关闭火炬开关或远程开关 (或数控 START 信号处于活动状态) 无的气流直流 LED OFF。 | 1. Problem in the torch and leads switch circuit (Remote pendant switch circuit).2. CNC Contoller device not providing Start signal.3. Failed components in unit. 1.在火炬和潜在顾客问题开关电路 (远程垂饰开关电路) 2。不提供开始 signal.3 CNC 控制器设备。单元中的失败的组件。 | 1. Take Torch and Leads (Remote Pendant) to Authorized Repair Facility. 2. Contact Controller manufacturer.3. Return to authorized service center for repair or replacement. 1.带火炬和潜在顾客 (远程挂件) 到授权的维修设施。2.请联系控制器 manufacturer.3。返回到授权的服务中心进行维修或更换。 |
FAULT and 85 PSI indicators flashing. 闪光的故障和 85 PSI 指标。 | 1. Upper O-Ring on torch head is in wrong position.2. Torch starter cartridge is stuck. 3. Worn or faulty torch parts.4. Shorted Torch.5. Temporary Short indicated by 5 blinks per second.6. Power Supply Failure (Standard rate of blinking) 1. o 形环火炬头上是错误的方位. 2 中。火炬起动器盒卡住。 3.磨损或有缺陷的火炬部分 4。短路的 Torch 5。5 眨眼每 second. 6 所指示的临时短。电力供应故障 (的闪烁的标准税率) | 1. Remove shield cup from torch; check upper O-Ring position; correct if necessary.2. Turn off power supply. Bleed down system pressure. Remove shield cup, tip and starter cartridge. Check starter cartridge lower end fitting for free movement. Replace if fitting does not move freely.3. Inspect torch consumable parts. Replace if necessary.4. Replace torch and leads or return to an authorized service center for repair.5. Release torch switch and reactivate.6. Return to autorized service center for repair or replacement. 1.删除火炬盾杯 ; 检查上 o 形位置 ; 如果纠正 necessary. 2。关闭电源供应。系统压力下流血。删除盾杯、 提示和初学者磁带。请检查起动器墨盒下端免费装运动。如果安装不会移动 freely. 3,替换。视察火炬消耗品部分。如果替换 necessary. 4。替换火炬和线索,或返回到 repair. 5 授权的服务中心。释放火炬开关和 reactivate. 6。返回到 autorized 服务中心进行维修或更换 |
No Fault lights on, no arc in torch. 对没有弧火炬的无故障灯 | 1. Failed components in unit. 1.失败单元中的组件 | 1. Return to an authorized service center for repair. 1.返回到修复一个授权的服务中心 |
FAULT and 85 PSI indicators flashing 闪光的故障和 85 PSI 指标 | 1. Internal Error | 1. Turn the ON / OFF switch OFF then back ON again. If that does not clear the fault, return to an authorized service center for repair. 打开在 ON / OFF OFF 开关,然后再对。如果是不会清除故障返回到修复一个授权的服务中心 |
Pilot arc is on but cutting arc will not establish 对是项试验弧但切割弧不会建立 | 1. Work cable not connected to work piece.2. Work cable/connector broken. 3. Failed components in unit. 1.工作没有连接到工作 piece.2 的电缆。工作断电缆/连接器。3.失败单元中的组件 | 1. Connect work cable.2. Replace work cable. 3. Return to an authorized service center for repair. 1.连接工作 cable 2。替换工作电缆。 3.回到修复授权的服务中心 |
Torch cutting is diminished 火炬切割是减少了 | 1. Incorrect current setting.2. Worn torch consumables.3. Poor work cable connection to work piece. 4. Torch being moved too fast.5. Excessive oil or water in torch.6. Failed components in unit. 1.不正确的当前 setting.2。戴火炬 consumables.3。穷人工作电缆连接到工作项。4.太被移动的火炬 fast.5。过多的油或水的 torch.6。单元中的失败的组件 | 1. Check and adjust to proper setting.2. Check torch consumables and replace as needed.3. Check the connection of the Work Lead to the work piece. 4. Reduce cutting speed.5. Refer to "Check air quality" in section 3 Torch.6. Return to an authorized service center for repair. 1.检查并调整到适当的 setting.2。签火炬耗材,并替换为 needed.3。请检查该工作会导致工件的连接。4.减少切割 speed.5。请参阅一节中的"检查空气质素"3 Torch.6。返回到修复一个授权的服务中心 |